Guide
What size air compressor to blow out sprinklers
The air has to push water out at about the zone’s own flow, and compressors are rated in a different kind of CFM.
Short answer
Size it from your largest zone's flow. Pushing a 10 GPM zone out at 50 PSI at its design flow takes about 5.9 SCFM of free air, so a 20 to 30 gallon compressor does it comfortably and a 6 gallon pancake does it in short bursts with waits to refill. Never exceed 80 PSI on PVC pipe or 50 PSI on polyethylene.
From zone GPM to compressor CFM
Colorado State University Extension sizes the compressor by dividing the zone's flow in gallons per minute by 7.5, because a cubic foot holds about 7.5 gallons: its example zone of 20 GPM at 30 PSI needs 2.7 CFM. That is right as far as it goes, but it is cubic feet of air at the pressure in the pipe. Compressors are rated in SCFM, free air at atmospheric pressure, and air squeezed to 30 or 50 PSI takes up a fraction of its free volume. So the compressor has to deliver more than the simple rule says:
| Zone flow | Air volume (GPM ÷ 7.5) | SCFM at 30 PSI | SCFM at 50 PSI |
|---|---|---|---|
| 6 GPM | 0.8 | 2.4 | 3.5 |
| 8 GPM | 1.1 | 3.3 | 4.7 |
| 10 GPM | 1.3 | 4.1 | 5.9 |
| 12 GPM | 1.6 | 4.9 | 7.1 |
| 15 GPM | 2.0 | 6.1 | 8.8 |
| 20 GPM | 2.7 | 8.1 | 11.8 |
Matching the design flow is what keeps the heads popped up and the water moving out as a slug. With less air, CSU warns, the air rides over the top of the water and leaves it lying in the low spots, which is exactly where a freeze splits a pipe. Their rule of thumb: if the heads stay up and air keeps flowing after the water is out, the compressor is big enough.
Finding your zone's GPM
- From the water meter: run one zone with nothing else on, read the meter, wait one minute, read it again. The difference is the zone's GPM.
- From the heads: add up the flow of every nozzle on the zone from the manufacturer's nozzle chart.
Many meters read in cubic feet rather than gallons; multiply a cubic-foot reading by 7.48. Size the compressor for the largest zone.
Pressure limits
Hunter Industries and CSU Extension give the same ceilings: 80 PSI for rigid PVC and 50 PSI for polyethylene (flexible black) pipe. Hunter adds that the pressure must stay below the rating of the weakest part on the zone, so check valves, heads and swing joints too. Set the compressor's regulator before you open the valve, not after. More pressure does not clear water faster; more volume does.
What each compressor actually does
A compressor that cannot match the zone's flow still works, if you let its tank do the heavy lifting. Starting full and blowing a 10 GPM zone at 50 PSI:
| Compressor | Pump (SCFM at 90 PSI) | Full flow from the tank | Then, share of design flow | Refill time |
|---|---|---|---|---|
| 6 gallon pancake | 2.6 | 100 s | 44 percent | 2.1 min |
| 20 gallon | 4 | 9.7 min | 68 percent | 4.5 min |
| 30 gallon | 5.1 | 29.6 min | 87 percent | 4.5 min |
| 60 gallon | 10.5 | continuous | 100 percent | 5.2 min |
The pump's rating at 90 PSI is a floor here: at 50 PSI the same pump delivers somewhat more, so the real figures are a little better. The pattern is what matters. A pancake moves the water at full flow for about 100 seconds, then needs about 2.1 minutes to refill from 50 PSI. Use it that way: close the compressor valve, let the tank fill, open the zone and blow until the heads spit mist, and repeat. Hunter recommends two or three short cycles per zone over one long one anyway, and warns against blowing dry pipe for long, since the friction heats it.
Irrigation contractors use towable compressors of 80 to 100 CFM or more, which Hunter recommends for any mainline of 2 in or less. They clear a zone in a couple of minutes and move on. A homeowner with one system and an afternoon does not need that; a 60 gallon machine matches a 10 GPM zone outright, and a 20 or 30 gallon one comes close. For another flow or tank, the tank size and runtime calculator gives the burst length.
Before you start
- Wear eye protection and do not stand over heads, valves or pipe while the system is under air (Hunter).
- Connect after the backflow preventer, never through it, and drain the backflow separately.
- Start with the zone highest and furthest from the compressor and work back toward it.
- Keep a zone open whenever air is connected, so the pipe is never pressurized with nowhere to go.